Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
Biosensors (Basel) ; 14(4)2024 Mar 27.
Article En | MEDLINE | ID: mdl-38667150

Since its first appearance in 1981, HIV-1 has remained a global concern. Current methods for diagnosing HIV-1, while effective, are mostly specific to a given subtype of HIV-1 and often require expensive equipment and highly trained individuals to collect and process the sample. It is necessary to develop a sensitive diagnostic method that can be administered with minimal equipment to provide better care in low-resource settings. Loop-mediated isothermal amplification is a rapid and sensitive method for detecting the presence of specific nucleic acid sequences. Herein we report the development and comparison of two different HIV LAMP assays, integrase and VPR, as well as the comparison between TRIZol and magnetic beads RNA extraction methods for each assay. Our analysis shows that the integrase assay was able to detect the virus from multiple subtypes in under 30 min with a variable limit of detection (LOD) that was dependent on the HIV-1 subtype.


HIV Infections , HIV-1 , Nucleic Acid Amplification Techniques , HIV-1/isolation & purification , HIV-1/genetics , Nucleic Acid Amplification Techniques/methods , Humans , HIV Infections/diagnosis , HIV Infections/virology , Molecular Diagnostic Techniques/methods , Limit of Detection , RNA, Viral/analysis
2.
Sensors (Basel) ; 23(19)2023 Oct 07.
Article En | MEDLINE | ID: mdl-37837121

Exosomes have gained recognition in cancer diagnostics and therapeutics. However, most exosome isolation methods are time-consuming, costly, and require bulky equipment, rendering them unsuitable for point-of-care (POC) settings. Microfluidics can be the key to solving these challenges. Here, we present a double filtration microfluidic device that can rapidly isolate exosomes via size-exclusion principles in POC settings. The device can efficiently isolate exosomes from 50-100 µL of plasma within 50 min. The device was compared against an already established exosome isolation method, polyethylene glycol (PEG)-based precipitation. The findings showed that both methods yield comparable exosome sizes and purity; however, exosomes isolated from the device exhibited an earlier miRNA detection compared to exosomes obtained from the PEG-based isolation. A comparative analysis of exosomes collected from membrane filters with 15 nm and 30 nm pore sizes showed a similarity in exosome size and miRNA detection, with significantly increased sample purity. Finally, TEM images were taken to analyze how the developed devices and PEG-based isolation alter exosome morphology and to analyze exosome sizes. This developed microfluidic device is cost-efficient and time-efficient. Thus, it is ideal for use in low-resourced and POC settings to aid in cancer and disease diagnostics and therapeutics.


Exosomes , MicroRNAs , Neoplasms , Humans , Point-of-Care Systems , Microfluidics
...